{"id":15614,"date":"2025-01-17T09:22:41","date_gmt":"2025-01-17T02:22:41","guid":{"rendered":"https:\/\/www.tid.vn\/?post_type=product&p=15614"},"modified":"2025-01-17T09:22:41","modified_gmt":"2025-01-17T02:22:41","slug":"honeywell-pro4200-controllers","status":"publish","type":"product","link":"https:\/\/tidvn883.mbws.vn\/en\/san-pham\/honeywell-pro4200-controllers","title":{"rendered":"Honeywell PRO4200 Controllers"},"content":{"rendered":"

Specifications:<\/strong><\/p>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
MODULE SPECIFICATIONS<\/strong><\/span><\/td>\nPRO4200 SERIES SINGLE READER MODULE (PRO42R1)<\/strong><\/span><\/td>\nPRO4200 SERIES DUAL READER MODULE (PRO42R2)<\/strong><\/span><\/td>\n<\/tr>\n
PORT<\/td>\nReader port 12\/24VDC @ 500mA, OSDP; Wiegand; Dt\/Clk*<\/td>\n2 Reader port 12\/24VDC @ 300mA, OSDP; Wiegand; Dt\/Clk*<\/td>\n<\/tr>\n
KEYPAD<\/td>\nKeypad multiplexed with card data<\/td>\n<\/tr>\n
WIRE SUPPORT<\/td>\nTwo-wire or one-wire bi-color LED support<\/td>\n<\/tr>\n
BUZZER SUPPORT<\/td>\nBuzzer support only with one-wire LED control<\/td>\n<\/tr>\n
ALARM INPUTS<\/td>\n2 supervised, general purpose alarm inputs with programmable circuit type<\/td>\n8 supervised, general purpose alarm inputs with programmable circuit type (only 6 supervised inputs available when using PRO22ENC1, PRO22ENC2 and PRO 22ENC5 enclosures)<\/td>\n<\/tr>\n
OUTPUT RELAYS (DOOR STRIKE(S)<\/td>\n1 output relay, form C, 5A 40 VDC<\/td>\n2 output relay, form C, 2A 30 VDC<\/td>\n<\/tr>\n
OUTPUT RELAYS<\/td>\n1 general purpose output relay, form C, 5A 30 VDC<\/td>\n2 general purpose output relay, form C, 5A 30 VDC<\/td>\n<\/tr>\n
MOUNTING<\/td>\nDesigned to be tile-mounted using the PRO22ENC4 enclosure<\/td>\nN\/A<\/td>\n<\/tr>\n
ALARM INPUT PROPERTIES<\/strong><\/td>\n<\/tr>\n
INPUTS<\/td>\nInputs may be assigned to door related functions or general purpose I\/O<\/td>\n<\/tr>\n
CIRCUIT TYPE<\/td>\nCircuit type – normally open, normally closed, non-supervised, supervised (with standard 1K or custom end-of-line resistance 200-10K)<\/td>\n<\/tr>\n
LINE CONDITIONING<\/td>\nLine conditioning – programmable sensitive hold time<\/td>\n<\/tr>\n
OUTPUT CONTROL PROPERTIES<\/strong><\/td>\n<\/tr>\n
OUTPUTS<\/td>\nOutputs may be assigned to door related functions or general purpose I\/O<\/td>\n<\/tr>\n
RELAY RATING<\/td>\nThe relay(s) are rated to handle the inductive loads of door locking devices S-4 SUPPRESSOR CABLE TO THE DOOR OPENER<\/td>\n<\/tr>\n
CONFIGURABLE<\/td>\nConfigurable as standard (energize to activate) or fail-safe (de-energize to activate)<\/td>\n<\/tr>\n
PULSE TIME<\/td>\n1-42,400 seconds, 1-255 for door relays<\/td>\n<\/tr>\n
RS485 PORT<\/td>\nRS485 port, 4,000 ft (1,250m) total bus length<\/td>\n<\/tr>\n
STANDARD SPEED<\/td>\n38.4 Kbps<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
MODULE SPECIFICATIONS<\/span><\/strong><\/td>\nPRO4200 SERIES SIXTEEN RELAY OUTPUT MODULE (PRO42OUT)<\/span><\/strong><\/td>\nPRO4200 SERIES SIXTEEN ALARM INPUT MODULE (PRO42IN)<\/span><\/strong><\/td>\n<\/tr>\n
ALARM INPUTS<\/td>\n2 dedicated (unsupervised) alarm inputs for tamper detection and power loss (tile-mounted only)<\/td>\n<\/tr>\n
ALARM INPUTS<\/td>\nN\/A<\/td>\n16 general purpose inputs with programmable circuit type<\/td>\n<\/tr>\n
OUTPUT RELAYS<\/td>\n12 general purpose output relays, form C, 5A 30 VDC
\n(16 are available when using PRO22ENC3
\ntile-mounted enclosure)<\/td>\n
2 general purpose, form C, 5A 30 VDC relays
\n(only one available when using PRO22ENC1, PRO22ENC2
\nand PRO22ENC5)<\/td>\n<\/tr>\n
OUTPUT CONTROL PROPERTIES<\/strong><\/td>\n<\/tr>\n
OUTPUT<\/td>\nAll 16-relay outputs in the tile-mount configuration
\n(1 rack mount) are available for general purpose I\/O<\/td>\n
Both relay outputs are available for general purpose I\/O<\/td>\n<\/tr>\n
DRY CIRCUIT LOGIC<\/td>\n\u00a0The 5A relays are rated to handle dry circuit logic (Resistive)<\/td>\nBoth relay outputs are rated to handle dry circuit logic (Resistive)<\/td>\n<\/tr>\n
PULSE TIME<\/td>\n1-32,400 seconds<\/td>\n<\/tr>\n
CONFIGURABLE<\/td>\nConfigurable as standard (energize to activate) or
\nfail-safe (de-energize to activate)<\/td>\n
\u00a0N\/A<\/td>\n<\/tr>\n
ALARM INPUT PROPERTIES<\/strong><\/td>\n<\/tr>\n
INPUTS<\/td>\n2 dedicated for tamper detection and power loss<\/td>\nAll 16 inputs may be assigned to door related functions or general purpose I\/O 2 dedicated for tamper and power loss<\/td>\n<\/tr>\n
CIRCUIT TYPE<\/td>\nN\/A<\/td>\nCircuit type – normally open, normally closed,
\nnon-supervised, supervised (with correct EOL)<\/td>\n<\/tr>\n
LINE CONDITIONING<\/td>\nN\/A<\/td>\nLine conditioning – programmable sensitivity and hold time<\/td>\n<\/tr>\n
COMMUNICATION FEATURES<\/td>\n<\/tr>\n
MEASUREMENTS<\/td>\nRS485 port, 4,000 ft (1,250m) total bus length per port<\/td>\n<\/tr>\n
SPEED<\/td>\n38.4 Kbps<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Professional Series Access Modules<\/p>\n

The PRO4200 professional series family of access control modules is designed for high density installations.<\/p>\n","protected":false},"featured_media":11287,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/tidvn883.mbws.vn\/en\/wp-json\/wp\/v2\/product\/15614"}],"collection":[{"href":"https:\/\/tidvn883.mbws.vn\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/tidvn883.mbws.vn\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/tidvn883.mbws.vn\/en\/wp-json\/wp\/v2\/comments?post=15614"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tidvn883.mbws.vn\/en\/wp-json\/wp\/v2\/media\/11287"}],"wp:attachment":[{"href":"https:\/\/tidvn883.mbws.vn\/en\/wp-json\/wp\/v2\/media?parent=15614"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}