{"id":15904,"date":"2025-01-20T16:24:05","date_gmt":"2025-01-20T09:24:05","guid":{"rendered":"https:\/\/www.tid.vn\/?post_type=product&p=15904"},"modified":"2025-01-20T16:24:06","modified_gmt":"2025-01-20T09:24:06","slug":"armatura-ahdu-1460","status":"publish","type":"product","link":"https:\/\/tidvn883.mbws.vn\/en\/san-pham\/armatura-ahdu-1460","title":{"rendered":"Armatura AHDU-1460"},"content":{"rendered":"

Specifications:<\/strong><\/p>\n

AHDU-1460 General Information<\/p>\n

Power Supply<\/strong> 802.3at\/af PoE \/ 9 \u2013 24 VDC \u00b1 20%, 550 mA max (excluding reader current)<\/p>\n

Master Host Interface<\/strong>
\nEthernet: 100Base-TX
\n256bit AES* symmetric encryption for Controller-to-Server and Controller-to-Controller communication<\/p>\n

Slave Host Interface<\/strong> BLE 5.2<\/p>\n

Third Host Interface<\/strong>
\nWi-Fi IEEE 802.11ac 5GHz, or 2.4GHz\/5GHz IEEE 802.11n
\n256bit AES* symmetric encryption for Controller-to-Server and Controller-to-Controller communication<\/p>\n

Ethernet Network Connection<\/strong>
\nPort 1:Ethernet: 100Base-TX
\nPort 2: Ethernet: 100Base-TX
\n(Configurable for Failover Port)<\/p>\n

RS-485 Connection<\/strong>
\nPort 1: Armatura RS-485 \/ OSDP V2.2
\nPort 2: Armatura RS-485 \/ OSDP V2.2
\nPort 3: Armatura RS-485 \/ OSDP V2.2
\n(Configurable for redundant ports 2 & 3)<\/p>\n

Number of Ports<\/strong>
\n2*TCP\/IP
\n3*RS-485
\n4*Wiegand<\/p>\n

Input Port<\/strong>
\nMonitor 4 states, resistance value (5% tolerance),
\nNormally open contact: use 1.2k, 2.2k. 4.7k or 10k\/
\nNormally closed contact: use 1.2k, 2.2k. 4.7k or 10k\/
\nTamper IO Input* Dedicated Control Panel
\nDedicated IC Control Fire Alarm IO Input & REX Input for Disaster Situation<\/p>\n

Outputs<\/strong>
\n4 relays,
\n4* Form-C with dry contacts<\/p>\n

Normally Open Contact Rating 5A @ 30Vdc<\/p>\n

Normally Closed Contact Rating 5A @ 30Vdc<\/p>\n

On-Board Display<\/strong>
\nSize: 2.4\u2033, Resolution: 320*240, TFT Display
\nQuickly view the status of the panel, connected doors and display configuration information<\/p>\n

On-Board Webserver<\/strong>
\nWeb server for system management and configuration
\nControl panel for monitoring controller status,
\nMonitoring & Configuration Device Connection Status, Performance Status,
\nServer master controller settings, Network status settings and monitoring,
\nIP access filter, Settings SSL\/TLS certificate,
\nAccess log export, Controller reset, Debug status monitoring,
\nOperational log monitoring, User management,
\nDate & time setting, Daylight Saving time setting
\nNTP server setting, General status, Controller information<\/p>\n

RFID Card Capacity<\/strong> 400,000 (1:N) \/ 800,000 (1:1)<\/p>\n

Maximum RFID Card Number Length<\/strong> Supports card number length up to 512 bits<\/p>\n

Mobile Authentication Capacity<\/strong>
\n400,000 (1:N) (Bluetooth)
\n400,000 (1:N) (NFC)
\n400,000 (1:N) (Dynamic QR Code)<\/p>\n

Fingerprint Capacity<\/strong> 50,000 (1:N) \/ 100,000 (1:1)<\/p>\n

Face Capacity<\/strong> 5,000 (1:N) \/ 100,000 (1:1)<\/p>\n

Palm Capacity<\/strong> 3,000 (1:N) \/ 5,000 (1:1)<\/p>\n

Transaction Buffer<\/strong> 300,000 Events<\/p>\n

Access Levels<\/strong> 100,000 Levels<\/p>\n

On-Board Access Control Points<\/strong> 4 on-board access points<\/p>\n

On-Board Reader Support<\/strong>
\n3 (OSDP over RS-485)
\nor
\n4 (Wiegand) with on-board IO<\/p>\n

Maximum Access Points<\/strong> 4<\/p>\n

Maximum Readers<\/strong> 8<\/p>\n

Maximum Inputs<\/strong> 384 (using Armatura AHEB-1602)<\/p>\n

Maximum Outputs<\/strong> 385 (using Armatura AHEB-0216)<\/p>\n

Maximum IO Board<\/strong> 24pcs (3 * High-speed RS-485 interfaces)<\/p>\n

Multi-Biometric Reader Interface \/ RFID<\/strong><\/span><\/p>\n

Input Voltage<\/strong> 12 -24 Vdc +\/- 10% adjustable, up to 500 mA per reader<\/p>\n

Maximum Input Current<\/strong> 12 -24 Vdc +\/- 10% adjustable, up to 500 mA per reader<\/p>\n

Protocol<\/strong> RS-485 AES-128, OSDP Secure Channel<\/p>\n

OSDP Mode<\/strong>
\n9600-115200 bps, OSDP V2.2, asynchronous, half duplex, 1 start bit, 8 data bits, and 1 stop bit.
\n3rd Party Reader: OSDP V2.2 or later supported<\/p>\n

Wiegand<\/strong> Read: supports up to 128 bit \/ Write: Supports 26\/34\/37 bit and other custom tag formats<\/p>\n

Tamper Input (Wiegand)<\/strong> TTL level, high > 3 V, low < 0.5 V, 5 mA source\/sink max<\/p>\n

Buzzer Output (Wiegand)<\/strong> TTL level, high > 3 V, low < 0.5 V, 5 mA source\/sink max<\/p>\n

LED Output (Wiegand)<\/strong> TTL level, high > 3 V, low < 0.5 V, 5 mA source\/sink max<\/p>\n

Input Data<\/strong>
\nSupports RS-485, OSDP, and Wiegand standards.
\nMaximum RS-485\/OSDP cable length: 3937ft. (1200m)
\nMaximum Wiegand Cable Length: 328ft (100m)<\/p>\n

IO Expansion Board Interface<\/strong><\/span><\/p>\n

Protocol<\/strong> RS-485 AES-128 Secure Channel, OSDP V2<\/p>\n

OSDP Mode<\/strong>
\n9600-115200 bps, OSDP V2.2, asynchronous, half-duplex, 1 start bit, 8 data bits, and 1 stop bit.
\nMaximum Cable Length: 2,000 ft. (609.6m)<\/p>\n

Input Data<\/strong>
\nOSDP and Wiegand standards supported.
\nMaximum Cable Length: 500 ft. (152m)<\/p>\n

Cable Requirements<\/strong><\/span><\/p>\n

Power & Relays<\/strong> One twisted pair, 18 to 16 AWG<\/p>\n

Ethernet Redundant Switch Port <\/strong>CAT-5, 330 ft. minimum. (100m)<\/p>\n

Ethernet<\/strong> CAT-5, 330 ft. (100m) minimum<\/p>\n

RS-485 Reader Port<\/strong>
\n9600-115200 bps, asynchronous, half-duplex, 1 start bit, 8 data bits, and 1 stop bit.
\nOne twisted pair with conductor and shield, 120 ohm resistor, 22-18 AWG,
\nMaximum cable length: 3937ft (1200m)<\/p>\n

RS-485 I\/O Device Port<\/strong>
\n9600-115200 bps, asynchronous, half-duplex, 1 start bit, 8 data bits, and 1 stop bit.
\nOne twisted pair with conductor and shield, 120 ohm resistor, 22-18 AWG
\nMaximum cable length: 3937ft (1200m)<\/p>\n

Redundant Switch Port RS-485<\/strong>
\n9600-115200 bps, asynchronous, half duplex, 1 start bit, 8 data bits, and 1 stop bit.
\nOne twisted pair with conductor and shield, 120 ohm resistor, 22-18 AWG,
\nMax cable length: 3937ft (1200m)<\/p>\n

Wiegand Port<\/strong> 20 AWG shielded Wiegand wire, 328ft. (100m)<\/p>\n

Mechanical<\/strong><\/span><\/p>\n

Dimensions<\/strong> 4.8\u201d W x 10.2\u201d L x 2.5\u201d H (122 x 260 x 62.5mm)<\/p>\n

Weight<\/strong> 30oz (830g)<\/p>\n

DIN Rail Mounting<\/strong>
\nDIN35 rail supported
\nCompatible with UTA89 Din Rail Adapter for screwing into circuit breakers (Sold separately)<\/p>\n

Wall Mounting<\/strong><\/span><\/p>\n

Body Material<\/strong> ABS-PC UL-94 V2<\/p>\n

Environment<\/strong><\/span><\/p>\n

Temperature<\/strong> -22\u00b0F ~ 158\u00b0F (-30\u00b0C~70\u00b0C), Operation & Storage<\/p>\n

Humidity<\/strong> 0-95% RHNC<\/p>\n

Security Rating<\/strong> Securely stores data in EAL 5+ certified electronic chips<\/p>\n

Software Interface<\/strong><\/span><\/p>\n

TCP\/IP Mode<\/strong> Ethernet: 100Base-TX<\/p>\n

TCP\/IP Protocol<\/strong> NTP, SNMP V2 \/V3, 802.1X, VLAN, SSH, MQTT, IPv4, IPv6, DNS, DDNS<\/p>\n

TCP\/IP Encryption<\/strong> TLS1.2 compliant, AES-256 end-to-end secure communication channel<\/p>\n

TCP\/IP Communication<\/strong> Spada Protocol over MQTT<\/p>\n

Supported Software<\/strong> Armatura One Security System<\/p>\n","protected":false},"excerpt":{"rendered":"