{"id":16122,"date":"2025-01-22T09:52:37","date_gmt":"2025-01-22T02:52:37","guid":{"rendered":"https:\/\/www.tid.vn\/?post_type=product&p=16122"},"modified":"2026-01-13T09:10:59","modified_gmt":"2026-01-13T02:10:59","slug":"toa-vx-3000pm","status":"publish","type":"product","link":"https:\/\/tidvn883.mbws.vn\/en\/san-pham\/toa-vx-3000pm","title":{"rendered":"TOA VX-3000PM"},"content":{"rendered":"
Specifications:<\/strong><\/p>\n Power supply<\/strong> 20 \u2013 33 V DC, removable terminal block (2 pins)<\/p>\n Current consumption<\/strong> LAN A, B<\/strong> Audio input<\/strong> Control input<\/strong> Control output Indicator<\/strong> LED SIGNAL (green) x 8, RUN (green) x 1, LINK\/ACT (green) x 2<\/p>\n Volume control<\/strong> 8-channel<\/p>\n Operation Input<\/strong> level setting switch x 1, IP address setting switch x 1<\/p>\n Operating temperature<\/strong> 0 \u00b0C to +40 \u00b0C<\/p>\n Allowable humidity<\/strong> 90 %RH or less (non-condensing)<\/p>\n Material<\/strong> Dimensions (W x H x D)<\/strong> 482 x 44 x 292.4 mm<\/p>\n Weight<\/strong> 3.2 kg<\/p>\n Accessories<\/strong> The VX-3000CT<\/strong> is a controller designed specifically for the VX-3000 evacuation system. We can activate public announcements and control input\/output volume by connecting the VX-3000CT to the VX-3000 via the network.<\/p>\n The device has 9 function keys and 8 volume control keys, supports up to 2 devices to connect to 1 VX-3000, and a system can be configured with up to 80 devices. The VX-3000CT can be mounted in an EIA equipment rack (1U size).<\/p>\n","protected":false},"featured_media":13649,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/tidvn883.mbws.vn\/en\/wp-json\/wp\/v2\/product\/16122"}],"collection":[{"href":"https:\/\/tidvn883.mbws.vn\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/tidvn883.mbws.vn\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/tidvn883.mbws.vn\/en\/wp-json\/wp\/v2\/comments?post=16122"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tidvn883.mbws.vn\/en\/wp-json\/wp\/v2\/media\/13649"}],"wp:attachment":[{"href":"https:\/\/tidvn883.mbws.vn\/en\/wp-json\/wp\/v2\/media?parent=16122"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}
\n0.33 A at 33 V DC input
\n0.35 A at 24 V DC input<\/p>\n
\nNumber of connection ports: 2 (LAN A, LAN B)
\nNetwork I\/F: 100BASE-TX
\nNetwork protocol: TCP, UDP, ARP, ICMP, RTP, IGMP, HTTP
\nSTP protocol: RSTP
\nPaging system: TOA audio packetization (*1)
\nAudio encoding method: PCM
\nAudio sampling frequency: 48 kHz
\nAudio quantification bits: 16 bits
\nConnecting devices: VX-3004F, VX-3008F, VX-3016F, NX-300, VX-3000CT, VX-3000PM, HUB network splitter
\nConnection port: RJ45
\nConnection cable: Category 5 (CAT5) twisted cable or higher
\nMaximum cable distance: 100 m<\/p>\n
\n8 inputs
\nInput level:
\ninput 1 \u2013 4: -60 dB (*2) \/ -40 dB (*2) \/ -20 dB (*2) \/ 0 dB (*2) selectable, input impedance 600 \u03a9, balanced
\ninput 5, 6: -20 dB (*2), input impedance 10 k\u03a9, unbalanced
\ninput 7, 8: 0 dB (*2), input impedance 10 k\u03a9, unbalanced
\nFrequency response: -60 dB (*2): 200 Hz \u2013 10 kHz, -2 dB \u00b1 3 dB
\n-40 dB (*2) \/ -20 dB (*2) \/ \u2013 dB (*2): 100 Hz \u2013 15 kHz, -2 dB \u00b1 3 dB
\nDistortion: 1 % or less
\nS\/N ratio: 60 dB or more
\nRemovable terminal block (6 pins x 2, 4 pins x 2)
\nOnly input 1 can be used with \u00f86.3 mm jack<\/p>\n
\n20 channels, no-voltage input, open voltage: 30 V DC,
\nShort circuit: 2 \u2013 10 mA
\nConnector: removable terminal block (10 pins x 2, 12 pins x 2)<\/p>\n
\nChannel 1 \u2013 5, relay (a contact), operating voltage: 30 V DC, control current: 1 A
\nChannel 6 \u2013 10, open collector output (biased), operating voltage: 30 V DC, control current control: 100 mA
\nConnector: removable terminal block (10 pins) x 2<\/p>\n
\nCase: Surface-treated steel plate, black, 30% gloss
\nVolume control housing: Acrylic resin, smoke gray<\/p>\n
\nRack mounting screws x 4, removable terminal block (6 pins) x 2,
\nRemovable terminal block (4 pins), jack removable connector (10 pins) x 4,
\nRemovable connector (12 pins) x 2, removable connector (2 pins) x 1<\/p>\n","protected":false},"excerpt":{"rendered":"